-1- h hitron universal input ac-dc medical & ite application external desktop switching adapter 10-12 watts green power single output hemg10 series output specification output voltage: see ratings chart. output current: see ratings chart. output wattage: typical 10-12 watts. output connector: optional. line regulation: typical 0.1%. load regulation: typical 2%. noise & ripple: 1.0% typical peak to peak. ovp: built-in, auto-recovery. adjustability: factory set. overload protection (olp): fully protected against output overload and short circuit. olp set at about 125-150% rating output wattage. consult the factory for olp setting. specification input specification input voltage: typical 90-264vac. input connector: 3 pole ac inlet iec320-c14(dt7) / 2 pole ac inlet iec320-c8(dt8). input frequency: 47-63hz. inrush current: 5.3arms at 230vac. input current: typical 0.2a at 115vac / 0.11a at 230vac dielectric withstand: meet iec60950-1 and iec60601-1. emi: meet en55011 and en55022 / fcc class b. hold-up time: typical 14.4ms at115vac/ 79ms at 230vac. leakage current: typical 0.3ma for class i. typical 0.1ma for class ii. no load power: less than 0.3w at 230vac. general specification efficiency: typical 75-86% (various with the output voltage) switching frequency: 60k hz. circuit topology: fixed frequency flyback circuit. transient response: output voltage returns in less than 1ms following a 25% load change. safety standard: meet medical standards ul60601-1/ en60601-1, and ite ul60950-1/en60950-1 class i for dt7(c14) or class ii for dt8(c8) operating temperature: 0 to +40c. storage temperature: -20c to +85c. cooling: free air convection. construction: impact resistant thermo- plastic enclosure case. power density: 0.8-0.96watts / cubic inch. note: (1) all measurements are at nominal input, full load, and +25c unless otherwise specified. (2) load regulation is measured at 115vac or 230vac in percentage to indicate the change in output voltage as the load is varie d from half load to full load ( ? %). (3) the exact obtainable load regulation depends upon the output cord selected and load current. upper data are for 6 ft. (2 m) cord awg#18 wires. (4) due to requests in market and advances in technology, specifications subject to change without notice. in application. features: ? accommodate universal ac input ? meet medical standards iec60601-1 & ite standards iec60950-1 ? no load power consumption <0.3 w ? emi meet en55011 & en55022 / fcc class b ? ce marking compliance
-2- output voltage / cu rrent ratings chart single output model no. ac inlet o/p voltage o/p current HEMG10-S050200-7 iec320-c14(dt7) 5.0vdc 2.0a hemg10-s050200-8 iec320-c8(dt8) 5.0vdc 2.0a hemg10-s090100-7 iec320-c14(dt7) 9.0vdc 1.0a hemg10-s090100-8 iec320-c8(dt8) 9.0vdc 1.0a hemg10-s120100-7 iec320-c14(dt7) 12.0vdc 1.0a hemg10-s120100-8 iec320-c8(dt8) 12.0vdc 1.0a hemg10-s150080-7 iec320-c14(dt7) 15.0vdc 0.8a hemg10-s150080-8 iec320-c8(dt8) 15.0vdc 0.8a hemg10-s240050-7 iec320-c14(dt7) 24.0vdc 0.5a hemg10-s240050-8 iec320-c8(dt8) 24.0vdc 0.5a mechanical dimensions: mm [inches] weight: 232.0g (8.18oz.) 100050mm for 5v-9v 200050mm for 12v-24v
|